Three Phase Solid State Relay
Product Overview
The Three Phase Solid State Relay provides electronic switching for compatible three-phase loads. HTH and HXGT-3 are the corresponding series references. The device sits in the power circuit and responds to the external controller, bringing the required switching arrangement into a defined assembly. The particular model determines the controlled poles and terminal connections.
Its function depends on the load wiring. Star and delta arrangements, neutral requirements and phase currents establish the circuit it serves. A motor also introduces starting conditions that differ from a continuously energized resistive load. These details affect the relay's operating duty and the heat produced during conduction. The control signal must match the input separately from the three-phase output supply. Ordinary three-phase switching does not itself provide motor reversal or every protective function. Those requirements belong to the equipment configuration, while the relay's main task is switching the connected load under the controller's command.
Features
Bolt Installation-Horizontal Type Three phase AC Solid State Relay
Triac/One-way SCR antiparallel NO output
DC-AC DC Singnal control AC load /AC-AC AC Signal control AC load
Optoelectronic devices Isolation
Zero crossing / Random Trigger Form
Built-in RC absorbing circuit
LED Status Indicator

Product Parameters
Electrical · Mechanical · Thermal
| Parameter | HXGT-3 48DA | HXGT-3 48AA |
|---|---|---|
| Product model | HXGT-3 48DA | HXGT-3 48AA |
| Control voltage | 3-32VDC | 80-250VAC |
| Control current | 6-25mA | 10-30mA |
| Reverse voltage | 32VDC | / |
| Guarantee close voltage | 1VDC | 30VAC |
| Guarantee open voltage | 3VDC | 80VAC |
| Load voltage | 28-480VAC | 28-480VAC |
| Load max current | 10A-75A | 10A-75A |
| Load mini current | 0.06A | 0.06A |
| Breakover voltage | ≤1.6VAC | ≤1.6VAC |
| Output leakage current | ≤8mA | ≤8mA |
| Medium withstand voltage | ≥2500VAC | ≥2500VAC |
| Insulating resistance | ≥100MΩ | ≥100MΩ |
| Switching time | ≤10mS | ≤10mS |
| Frequency range | 50-60Hz | 50-60Hz |
| Operating temperature | -20-70°C | -20-70°C |
| Load current safety factor | resistive load 50-60%; inductive load 30-40% | resistive load 50-60%; inductive load 30-40% |
Typical Application
Where this module is used




Customized
Factory-direct flexibility
Product Highlights
FAQ
Common questions
Q: Is phase-loss protection automatically included?
A: No such function should be assumed. Check the model configuration and provide system protection where required.
Q: Can it serve directly as a motor reversing controller?
A: An ordinary switching arrangement is not automatically a reversing system; the required phase-changing and interlocking functions must be established.