Three Phase Motor Reversing Solid State Relay

Three Phase Motor Reversing Solid State Relay
The Three Phase Motor Reversing Solid State Relay is a solid-state relay (SSR) specifically designed for three-phase 380 VAC mo-tors to control forward and reverse rotation. It employs a thyristor-based electronic switching design with no mechanical contacts to ensure safe and reliable control of three-phase mo-tor rotation in both directions. The product supports external signal inputs of 10~32 VDC (≤30 mA) and features built-in RC snubber circuits, varistors, and interlock protection circuits. It includes red and green LED status indicators, a reinforced 4 mm heat sink baseplate, and is encapsulated with epoxy resin, making it suitable for motor forward and reverse control applications in industrial environments.
Send Inquiry

Product Overview

The Three Phase Motor Reversing Solid State Relay is a solid-state relay (SSR) specifically designed for three-phase 380 VAC mo-tors to control forward and reverse rotation. It employs a thyristor-based electronic switching design with no mechanical contacts to ensure safe and reliable control of three-phase mo-tor rotation in both directions. The product supports external signal inputs of 10~32 VDC (≤30 mA) and features built-in RC snubber circuits, varistors, and interlock protection circuits. It includes red and green LED status indicators, a reinforced 4 mm heat sink baseplate, and is encapsulated with epoxy resin, making it suitable for motor forward and reverse control applications in industrial environments.

 

Product Parameters

Electrical · Mechanical · Thermal

Parameter Value
Control voltage 10~32VDC (12V or 24V recommended)
Control current ≤30mA (input circuit)
Public port Negative electrode
Response time ≤10ms (On/Off)

 

Terminal markings

Type

Feature description

Wiring requirements

L1, L2, L3

AC input terminal

Three-phase power input (line voltage 380VAC)

Connect to the three-phase live wires of power grid

U, V, W

AC output terminal

Motor output terminal

Connecting the windings of three-phase motor

 

+

Forward control terminal

Forward rotation signal input (active high)

When connected to positive terminal of external power

source (10~32 VDC), green light turns on.

-

Control common terminal

Input signal negative terminal (0V reference)

Connect to negative terminal of external power source

 

+

Reverse control terminal

Inverting signal input (active high)

When connected to positive terminal of external power

source (10~32 VDC), red light turns on.

 

Description of Features and Functions

Forward/Reverse Interlock Protection

When the forward signal is active and a reverse signal is simultaneously applied, the motor operates normally in the forward direction, while the reverse operation is forcibly shut down to prevent a direct short circuit between phase lines.

Status Indication

Green LED: Steady on indicates that the forward signal is active and the motor is operating in the forward direction; off indicates that the

forward signal is inactive or a fault has occurred.

Red LED: Steady on indicates that the reverse signal is active and the motor is operating in reverse; off indicates that the reverse signal

is inactive or a fault has occurred.

Surge and Overvoltage Protection

Varistor Surge Suppression

A built-in high-energy varistor is connected in parallel on the three-phase input side (between L1/L2/L3 and U/V/W). This limits the peak input voltage to no more than 600 VAC (rms).

RC Snubber Circuit

An internal parallel RC snubber is used to absorb back-EMF spikes when the motor stops (such as high-frequency, high-voltage spikes caused by the release of stored energy in the motor windings' inductance). The RC circuit dissipates energy through the resistor and absorbs high-frequency pulses via the capacitor, thereby suppressing voltage spikes at the output.

 

User and Operating Guide

Wiring Procedure

Disconnect the three-phase power supply and the external control power supply to ensure the equipment is de-energized.

Connect the three-phase power supply (L1/L2/L3) to the mains and (U/V/W) to the motor according to the terminal definitions.

Connect the control circuit: Connect the positive terminal of the external 10~32 VDC power supply to either the (+ Forward) or (+ Reverse) terminal; and connect the negative terminal of the power supply to the (-) common terminal.

Check that all connections are secure; apply power only after confirming everything is correct.

Start and Stop

Forward Start: Connect the positive terminal of the external control power supply to the (+ Forward) terminal; leave the (Reverse)

terminal open. The green LED will light up, and the motor will begin rotating forward.

Reverse Start: First stop forward rotation. After the motor has come to a complete stop (recommended interval of ≥2 seconds), connect the positive terminal of the external control power supply to the (+ Reverse) terminal, leaving the Forward terminal open. The red LED will light up, and the motor will begin rotating in reverse.

Stop: Disconnect all external control signals. The LEDs will turn off, and the motor will stop running

 

Typical Application

Where this module is used

Conveyor Belt Direction Control
Conveyor Belt Direction Control
Crane Hoist Up-Down Control
Crane Hoist Up-Down Control
Industrial Rolling Gate Opener
Industrial Rolling Gate Opener
Machine Tool Spindle Reversing
Machine Tool Spindle Reversing

Customized 

Packages includes: Standard molded case panel-mounted,

Important Notes

Electrical Safety

The input control voltage must not exceed 32VDC; otherwise, the control circuit may be damaged.

Short-circuiting the output terminals (U/V/W) is strictly prohibited, as this will cause permanent damage to the solid-state relay.

Heat Dissipation Requirements

The product is equipped with a 4 mm thickened heat-dissipating base plate. During installation, ensure tight contact with the heat sink

mounting surface (applying thermal grease is recommended) to ensure efficient heat dissipation.

Avoid using the product in enclosed, high-temperature (>85°C), or poorly ventilated environments; implement additional cooling measures (such as fans) if necessary.

Maintenance and Replacement

The product is fully encapsulated with epoxy resin and contains no removable internal components; non-professionals are prohibited from disassembling it.

Periodically inspect the exterior for cracks, deformation, or burn marks; if any abnormalities are found, immediately stop using the product and replace it.

 

Electrical Safety

The input control voltage must not exceed 32VDC; otherwise, the control circuit may be damaged.

Short-circuiting the output terminals (U/V/W) is strictly prohibited, as this will cause permanent damage to the solid-state relay.

Heat Dissipation Requirements

The product is equipped with a 4 mm thickened heat-dissipating base plate. During installation, ensure tight contact with the heat sink

mounting surface (applying thermal grease is recommended) to ensure efficient heat dissipation.

Avoid using the product in enclosed, high-temperature (>85°C), or poorly ventilated environments; implement additional cooling measures (such as fans) if necessary.

Maintenance and Replacement

The product is fully encapsulated with epoxy resin and contains no removable internal components; non-professionals are prohibited from disassembling it.

Periodically inspect the exterior for cracks, deformation, or burn marks; if any abnormalities are found, immediately stop using the product and replace it.

 

Hot Tags: three phase motor reversing solid state relay, China three phase motor reversing solid state relay manufacturers, suppliers, factory, Single Phase AC Voltage Regulator, Single Phase Rectifier Controller, Single Phase Thyristor Controller, Three Phase Thyristor Controller, Three Phase Voltage Controller, thyristor power modules

Request a Quote

3 fields only