Three Phase Controlled Rectifier Module
Product Overview
The Three Phase Controlled Rectifier Module converts a three-phase AC supply into an adjustable rectified DC output for industrial power-control applications. Thyristor firing is controlled to vary the DC output delivered to the load, giving the Three Phase Controlled Rectifier Module a different operating purpose from an AC voltage regulator. Its integrated power stage and isolated command circuit support applications where DC heating, electrochemical processing or other controlled-DC loads require adjustable power from a three-phase source. Manual adjustment and standard analog command signals can be used according to the control system configuration.
Typical Applications
Typical uses for the Three Phase Controlled Rectifier Module include DC resistance heating, electroplating tanks, electrolysis equipment, industrial ovens with DC heater circuits, welding power sections and inductive loads requiring controlled rectified power. For these applications, output waveform, allowable ripple and any external filtering should be considered together with the electrical requirements of the load.
Performance Features
Rated main-circuit supply: 380 VAC with ±20% tolerance.
Separate operating power supply: 100~240 VAC.
The auxiliary output is 12 VDC, 300 mA for cooling-fan power. The module can also connect to the company's RS485 communication module where computer-linked control or upgrading is needed.
External commands can be provided by 0~5 VDC, 0~10 VDC or 4~20 mA signals. Manual control is available using a 10K/2W
potentiometer, giving an alternative to remote analog control.
Red, green and blue LEDs provide visual indication for power, output and high-temperature/protection states,
helping operators identify the current operating condition.
The internal temperature-protection threshold is 85°C.
The rectifier provides stable, linear adjustment from zero to the specified maximum output voltage.
A configurable soft-start function reduces electrical stress during energization; the standard delay is 2 seconds and can be set within
a 0–60 second range.
The stated three-phase design does not require phase-sequence identification, reducing wiring complexity.
Isolation between the command electronics and the main thyristor circuit provides electrical separation between control and power sections.
Product Parameters
Electrical · Mechanical · Thermal
|
Function |
Input voltage range |
Power supply |
Control voltage |
Control current |
Resistance of manual potentiomete |
Cooling |
Ambient temperature |
Output voltage |
|
Arms |
mA |
VDC |
mA |
KΩ |
m/s |
°C |
VDC |
|
|
Thyristor three phase rectifying and voltage adjusting |
40~440V |
12V/400 |
0-5 |
4-20 |
10 |
air cooling heatsink, wind speed≥6 |
-30~+40 |
0-513 |
|
Parameter |
Nominal current |
Max.working current |
Interdiction voltage of SCR |
Frequency |
Dv/dt |
Di/dt |
Breaking leakage current(Max.) |
Making voltage drop(Max.) |
Insulating voltage (terminal/soleplate) |
Weight |
|
Unit |
Arms |
Arms |
Vpk |
Hz |
V/sec |
A/sec |
mA rms |
V rms |
V rms |
kg |
|
Value
|
50 |
3x50 |
1200 |
50/60 |
500 |
100 |
≤8 |
1.6 |
≥2500 |
0.425 |
|
70 |
3x70 |
1200 |
50/60 |
500 |
100 |
≤10 |
1.6 |
≤2500 |
0.425 |
|
|
120 |
3x120 |
1200 |
50/60 |
500 |
100 |
≤10 |
1.8 |
≤2500 |
0.425 |
|
|
200 |
3x200 |
1200 |
50/60 |
500 |
100 |
≤10 |
1.8 |
≤2500 |
0.425 |
|
|
250 |
3x250 |
1200 |
50/60 |
500 |
100 |
≤15 |
1.8 |
≤2500 |
2.2 |
|
|
350 |
3x350 |
1200 |
50/60 |
500 |
100 |
≤15 |
1.8 |
≤2500 |
2.2 |
|
|
500 |
3x500 |
1200 |
50/60 |
500 |
100 |
≤20 |
1.8 |
≤2500 |
2.2 |
Typical Application
Where this module is used




Customized
Factory-direct flexibility
Product Highlights
FAQ
Common questions
Q: Can the Three Phase Controlled Rectifier Module be used as a complete constant-current power supply?
A: Not automatically. Constant-current operation requires the appropriate feedback and regulation functions in the selected control configuration.
Q: When should additional DC filtering be considered?
A: Filtering depends on the rectified waveform and the load's acceptable ripple level. Evaluate these requirements before specifying external filter components.
Hot Tags: three phase controlled rectifier module, China three phase controlled rectifier module manufacturers, suppliers, factory, Motor Reversing SSR, Single Phase Rectifier Controller, Single Phase Thyristor Controller, Three Phase Rectifier Controller, Three Phase Thyristor Controller, Three Phase Voltage Controller
Request a Quote