D Type Water Cooled Heat Sink for Capsule Thyristor
Product Overview
The D Type water cooled heat sink for capsule thyristor removes heat from a compatible thyristor assembly through a circulating liquid circuit. The D-type reference identifies the corresponding product. Its contact with the device is the starting point of the cooling path: heat crosses that interface before passing into the water and out to the rest of the cooling system.
In a pressure-mounted stack, the clamp and contact surfaces affect this heat transfer. They work with the heatsink rather than independently of it. The device's operating losses establish the thermal duty, while water temperature, flow and the internal cooling arrangement influence the result. The individual drawing defines the D-type unit's dimensions and pipe connections. Its electrical relationship with the surrounding assembly must also follow the equipment design; a cooling body is not automatically an insulating component. The device, clamp, heatsink and water circuit together form the working installation.
Feature
Compatible with SS14, SS15 Serie
Water Cooling Heatsinks respectively,
High efficiency heat transfer water cooling design inside the heatsink
Ultralow low thermal resistance,high heatsinking capability, Manifold mounting structure
Application
UHP capsule device
High-power eliminator supply, High-power induction heating supply
Product Parameters
Electrical · Mechanical · Thermal
DSS3, DSS5, DSS6, DSS8 Water Cooling Heatsink (G-11)
|
Type |
Outline size (mm) |
Mounting size (mm) |
Maximum surface dimension |
Applicable case surface |
Thermal resistance |
||||||||||
|
L |
L1 |
L2 |
L3 |
H |
H1 |
H2 |
H3 |
D1 |
D2 |
D3 |
Wmax |
(mm) |
(mm) |
(°C/W) |
|
|
DSS3 |
140 |
70 |
50 |
40 |
118 |
25 |
88 |
25 |
Ø8.2 |
M5x7 |
M3x6 |
135 |
40x40 |
Ø19-Ø34 |
0.030 |
|
DSS5 |
170 |
88 |
57 |
50 |
130 |
30 |
100 |
30 |
Ø11 |
M6x15 |
M3x6 |
155 |
50x50 |
Ø34-Ø40 |
0.026 |
|
DSS6 |
180 |
93 |
59.5 |
55 |
151 |
35 |
121 |
30 |
Ø11 |
M6x15 |
M3x6 |
155 |
55x55 |
Ø34-Ø45 |
0.022 |
|
DSS8 |
193 |
100 |
62 |
60 |
190 |
50 |
160 |
30 |
Ø11 |
M6x10 |
M3x6 |
160 |
60x60 |
Ø34-Ø47 |
0.018 |
HSS3-Type Water Cooling Heatsink (G-15)
|
Type |
Maximum surface dimension |
Applicable case surface |
Thermal resistance |
Weigh |
|
(mm) |
(mm) |
(°C/W) |
(kg) |
|
|
HSS3 |
40x40 |
Ø19-Ø34 |
0.030 |
2.2 |
Product Views & Dimensions
Illustration only
Typical Application
Where this module is used




Customized
Factory-direct flexibility
Product Highlights
FAQ
Common questions
Q: Does the heatsink provide electrical insulation by default?
A: No. Its electrical role must be established from the construction and the equipment's insulation arrangement.
Q: Why review the clamp when replacing a cooling component?
A: In a pressure assembly, mechanical loading affects the contact through which heat leaves the device.
Hot Tags: d type water cooled heat sink for capsule thyristor, China d type water cooled heat sink for capsule thyristor manufacturers, suppliers, factory, Air cooled heat sink for capsule thyristor, D Type Water Cooled Heat Sink For Capsule Thyristor, Power Device Air Cooling Heat Sink, Semiconductor Water Cooling Heatsink, SS2X Series Water Cooled Heat Sink For Capsule Thyristor, Water Cooling Heat Sink
Request a Quote