Electroplating Rectifier
Product Overview
The Rectifying Device for Electroplating supplies DC power for compatible plating and electrochemical processes. KDF and KHF/KHS identify the corresponding equipment families. Its output supports the electrical conditions required at the process load, with the particular configuration determining the available regulation and control functions. The relevant duty comes from the production process rather than simply from the largest available current rating.
Workpiece area, specified current density and the way parts are loaded influence the current required. Voltage, ripple limits and operating time complete the electrical demand. Constant-current, constant-voltage, reverse or pulsed operation are distinct functions that belong to the selected equipment configuration. The installation also includes the high-current connections between the rectifier and load. Cooling, ventilation and the surrounding environment affect where the unit can operate as intended. Together, these details connect the power supply to the actual plating process and the production cycle it is expected to serve.
Feature
Analog controller, Function of voltage stabilizing and steady slow, Closed loop control
Intelligent PI adjust, Precision≤3%, Preiodically switching
American integration digital control system, Function of soft startup and slow stop
Application
Industrial electroplate, Cathode oxidation, Electrolysis, Disposal of sewage
DC power supply
Graphite furnace heat up
Product Parameters
Electrical · Mechanical · Thermal
| Specification | External dimension H×W×T | Note |
|---|---|---|
| KDA-300A/24V | 1200×600×600 | - |
| KDA-500A/12V | 1200×600×600 | - |
| KDF-1000A/12V | 1600×650×600 | - |
| KDF-1000A/24V | 1600×650×600 | - |
| KDF-2000A/12V | 1600×650×600 | - |
| KDF-2000A/18V | 1600×700×600 | - |
| KDF-2000A/24V | 1600×700×600 | - |
| KDF-3000A/12V | 1600×800×600 | - |
| KDF-3000A/18V | 2000×800×600 | Transformer external |
| KDF-3000A/24V | 2000×800×600 | Transformer external |
| KDS-6000A/12V | 1600×800×600 | Transformer external |
| KDS-6000A/24V | 1600×800×600 | Transformer external |
| KHF-3000A/75V | 2200×800×800 | Transformer excluding |
| KHF-3000A/125V | 2200×800×800 | Transformer excluding |
| KHF-3000A/250V | 2200×800×800 | Transformer excluding |
| KHF-3000A/400V | 2200×800×800 | Transformer excluding |
| KHS-6000A/75V | 2200×800×800 | High voltage cabinet and transformer excluding |
| KHS-6000A/125V | 2200×800×800 | High voltage cabinet and transformer excluding |
| KHS-6000A/250V | 2200×800×800 | High voltage cabinet and transformer excluding |
| KHS-6000A/400V | 2200×800×800 | High voltage cabinet and transformer excluding |
Typical Application
Where this module is used




Customized
Factory-direct flexibility
Product Highlights
FAQ
Common questions
Q: Does more current always improve the coating result?
A: No. Current density must match the specific process and its workpiece and bath conditions.
Q: Are pulse and reverse output included automatically?
A: No. Confirm these functions for the individual model; ordinary rectification does not establish either capability.
Hot Tags: electroplating rectifier, China electroplating rectifier manufacturers, suppliers, factory, Battery Charging Rectifier, DC Battery Charging System, Electroplating Power, High Current Plating Rectifier, Industrial Battery Charger, Industrial Rectifier System
Request a Quote