Single Phase Semi-Controlled Rectifier Bridge
Product Overview
The Single Phase Semi-Controlled Rectifier Bridge uses diode and thyristor branches to obtain a controlled DC-side output from a suitable single-phase supply. An external firing arrangement determines when the thyristors conduct, providing the basis for adjusting average output. The bridge combines those power paths into the connection arrangement shown in the individual model's circuit diagram.
The load affects the result. A resistive circuit and an inductive circuit may produce different current continuity, so output behaviour belongs to the complete bridge, trigger and load combination. Any freewheeling path must also be established from that circuit. Semi-controlled operation differs from a fully controlled bridge and does not automatically provide the same operating modes. The component itself does not supply every filtering or feedback function. Its purpose is the controlled rectifying stage, with terminal connections and the cooling interface linking it to the surrounding power supply and control equipment.
Feature
Package with DCB ceramic base plate
Isolation voltage 3600V~
Planar passivated chips
1/4" fast-on terminals
Product Parameters
Electrical · Mechanical · Thermal
|
Type |
Vrrm Vdrm |
Id@Ts |
Ts |
Itsm Ifsm @Tjmax |
Vt(to) @Tjmax |
rt(to) @Tjmax |
Rth(j-s) per chip |
Tj |
Case |
外形 Outline |
|
V |
A |
°C |
A |
V |
mΩ |
K/W |
°C |
|||
|
HSK50B06UF |
600 |
46 |
80 |
400 |
0.8 |
11 |
0.45 |
-40~+150 |
2 |
C-49 |
|
HSK50B |
800-1600 |
51 |
80 |
270 |
0.8 |
13 |
1.7 |
-40~+150 |
2 |
C-49 |
|
HSK55B06F |
600 |
54 |
80 |
440 |
0.9 |
16 |
1.2 |
-40~+150 |
2 |
C-49 |
|
HSK55B12F |
1200 |
57 |
80 |
550 |
1.2 |
22 |
0.9 |
-40~+150 |
2 |
C-49 |
|
Type |
Vrrm |
Vvrms |
Idavm |
@TH |
@Tc |
Ifsm 10ms Tvj45°C |
Vto |
rt (mohms) |
Tvjm |
Rthjc perchip |
Rthjh perchip |
Ckt Diag |
Package style |
Status |
|
V |
V |
A |
°C |
°C |
A |
V |
°C |
K/W |
K/W |
|||||
|
HVHF15 |
1400 |
440 |
15 |
85 |
- |
190 |
1.00 |
40 |
125 |
2.40 |
3.00 |
VHF |
FO-F-A |
Active Part |
|
HVHF36 |
1400 |
440 |
36 |
85 |
- |
320 |
0.85 |
13 |
125 |
1.15 |
1.55 |
VHF |
FO-F-A |
Active Part |
|
HVHF28 |
1400 |
440 |
28 |
85 |
- |
300 |
0.90 |
15 |
125 |
1.40 |
2.00 |
VHF |
FO-F-A |
Active Part |
|
HVHF25 |
800 |
250 |
32 |
- |
85 |
200 |
0.85 |
27 |
125 |
1.30 |
1.80 |
VHF |
ECO-PAC1 |
Active Part |
Product Views & Dimensions
Illustration only
Typical Application
Where this module is used


Customized
Factory-direct flexibility
Product Highlights
FAQ
Common questions
Q: Can it directly replace a fully controlled bridge?
A: No direct equivalence should be assumed. Circuit function and trigger configuration need to be reassessed.
Q: Are external trigger signals required?
A: The thyristor branches need suitable triggering; confirm whether any relevant electronics are included in the specific configuration.
Hot Tags: single phase semi-controlled rectifier bridge, China single phase semi-controlled rectifier bridge manufacturers, suppliers, factory, AC DC Bridge Rectifier, High Current Bridge Rectifier, High Power IGBT Module, High Speed Diode Module, Single Power Thyristor, Thyristor Diode Module
Request a Quote